Highlander™ Arterial catheter Highlander™ 014 PTA Balloon Dilatation Catheter

Highlander™ 014 PTA Balloon Dilatation Catheter

4 mm x 120 mm Balloon, 150 cm long catheter

Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon
Contact Us
Icon to close thank you modal
Thank you for contacting our sales team!
A sales representative will get in touch with you shortly.
Onsite Visiting
Location Icon
850 W. Rio Salado Parkway, Tempe, Arizona 85281 United States
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Fax Icon
1.800.440.5376
Overview

The Highlander™ 014 PTA Balloon Dilatation Catheter is a fiber-based, non-compliant balloon that is designed to deliver highly precise diameters and lengths relative to labeled sizing, even at high pressures.

 

  • Highly Precise Sizing
    • In bench testing, the Highlander™ 014 PTA Balloon Dilatation Catheter provided more precise sizing relative to labeled diameter, on average, at both Nominal Pressure and Rated Burst Pressure (RBP) compared to select leading competitors. 1    

 

  • Highly Controlled Compliance
    • In bench testing, the Highlander™ 014 PTA Balloon Dilatation Catheter had significantly less outer diameter and longitudinal growth, on average, between Nominal Pressure and RBP compared to select leading competitors. 2

 

  • Unmatched Strength
    • The Highlander™ 014 PTA Balloon Dilatation Catheter has the largest working pressure range and highest RBP of any 0.014 or 0.018 PTA balloon. 3
    • First and only fiber-based non-compliant balloon available on an 0.014 guidewire platform. 3

 

  • Low Profile
    • The Highlander™ 014 PTA Balloon has 4F sheath compatibility across all sizes.
true
Features and Benefits
Promotional Story
false
References

1  Accuracy measurements based on variance in balloon outer diameter between Nominal Pressure (NP) and Rated Burst Pressure (RBP) compared to labeled diameter for 2 mm balloons. Balloon outer diameters are measured at center of the balloon at NP and at RBP.  Mean results reported in mm, as follows: Highlander™ 014 Balloon (NP: 1.97, RBP: 2.00); Armada™ 14 (NP: 1.88, RBP: 2.01); Coyote™ (NP: 1.82, RBP: 2.02); and Pacific Plus™ (NP: 2.04, RBP: 2.32). All balloons tested were 2x150 mm, besides Armada™ 14 which was 2x200 mm. N=5 for all balloons tested. Data on file. BD, Tempe, AZ. Bench data may not be indicative of actual clinical performance. Different test methods may yield different results.

 Outer diameter measurements taken from center of balloon at NP and RBP. Mean results reported for percentage outer diameter growth, as follows: Highlander™ 014 Balloon (2.37%); Jade™ 014 (4.73%); Armada™ 14 (7.49%); Nanocross™ (9.02%); and Coyote™ (14.93%). Length measurements taken from point of cone taper at proximal and distal ends of the balloon at NP and RBP. Mean results reported for percentage longitudinal growth, as follows: Highlander™ 014 Balloon (0.67%); Jade™ 014 (2.18%); Armada™ 14 (2.30%); Nanocross™ (2.58%); and Coyote™ (2.84%). All balloons tested were 4x150 mm, besides Armada™ 14 which was 4x200 mm. N=5 for all balloons tested. Bench test data on file. BD, Tempe, AZ. Bench test results may not necessarily be indicative of clinical performance. Different test methods may yield different results.

 

3  As of January 2023. US market only.  EVT Device Guide, PTA Balloons.  Competitive balloon material information obtained from product web pages and/or 510(k) summaries.

 Please consult product labels and instruction for use for indications, contraindications, hazards, warnings and precautions.

BD-81022

true
Specification

GTIN - Each

00801741213656

1


Balloon Diameter

4 mm

Balloon Length

120 mm

Catheter Length

150 cm

Sheath Size

4F

Rated Burst Pressure (atm)

30

Nominal Pressure (atm)

6

GTIN

GTIN - Each 00801741213656 1

Product Basic Specification

Balloon Diameter 4 mm
Balloon Length 120 mm
Catheter Length 150 cm
Sheath Size 4F
Rated Burst Pressure (atm) 30
Nominal Pressure (atm) 6
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions
false
References
false
Related Products
RELATED PRODUCTS NOT AVAILABLE
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false
false