{"AlternateComparison":false,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
OptiFix™ OptiFix™ Open Absorbable Fixation System

OptiFix™ Open Absorbable Fixation System - 20 Absorbable Fasteners

Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representative will get in touch with you shortly.
Ordering
Phone Icon
1.800.556.6756
BDISurgery@bd.com
Onsite Visiting
Location Icon
100 Crossings BoulevardWarwick, Rhode Island 02886United States
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Monday to Friday 8:15 AM to 6:00 PM EST
Fax Icon
1.800.531.4124
Custserv.davol@bd.com
Shipping a Product Back
Location Icon
100 Crossings Boulevard, Warwick, Rhode Island 02886, United States
Overview
Optimized Design

For Open Ventral Hernia Repair


The OptiFix™ Open Absorbable Fixation System was designed for improved ease of use when fixating surgical meshes to the abdominal wall in open ventral hernia procedures by reducing limitations that exist with current laparoscopic straight devices. Combined with Ventrio™ ST, it provides a full system for open ventral hernia repair.

true
Features and Benefits
Promotional Story
false
References

1. Preclinical data on file. Results may not correlate to clinical outcomes.

2. C. R. Bard Inc., bench data on file.

3 Preclinical data on file. Results may not correlate to clinical outcomes.

4 Survey of surgeons attending pre-clinical lab.

Results may not correlate to clinical outcomes. Data on file.

OptiFix™ Open Absorbable Fixation System

Indications

The OptiFix™ Open Absorbable Fixation System is indicated for the fixation of surgical mesh to tissues during open surgical procedures, such as hernia repair.

Contraindications

This device is not intended for use except as indicated. 2. Do not use this device where hemostasis cannot be verified visually after application

Contraindications associated with open surgical procedures relative to mesh fixation apply, including but not limited to:

  • Fixation of vascular or neural structures
  • Fixation of bone and cartilage,
  • Situations with insufficient ingrowth of tissue into the mesh over time, which could result in inadequate fixation once the fastener is absorbed.
  • Carefully inspect the area in the vicinity of the tissue being fastened to avoid inadvertent penetration of underlying structures such as nerves, vessels, viscera or bone. Use of the OptiFix™ Open Absorbable Fixation System in the close vicinity of such underlying structures is contraindicated. For reference, the length of the fastener below the fastener head is 6.1 mm, the fastener head is another 0.6 mm (total 6.7 mm). This device should not be used in tissues that have a direct anatomic relationship to major vascular structures. This would include the deployment of fasteners in the diaphragm in the vicinity of the pericardium, aorta, or inferior vena cava during diaphragmatic hernia repair.  

 

Warnings

 The  OptiFix™ Open Absorbable Fixation System is intended for Single Use Only – DO NOT RESTERILIZE. Reuse, reprocessing, resterilization or repackaging may compromise the structural integrity and/or essential material and design characteristics that are critical to the overall performance of the device and may lead to device failure which may result in injury to the patient. Reuse, reprocessing, resterilization or repackaging may also create a risk of contamination of the device and/or cause patient infection or cross infection, including, but not limited to, the transmission of infectious diseases from one patient to another. Contamination of the device may lead to injury, illness or death of the patient or end user. Do not use beyond the expiration date on the package. Prior to use, carefully examine package and product to verify neither is damaged and that all seals are intact. Do not use if the foil pouch or package is damaged or open, or if the center of the temperature indicator on the foil pouch is black. As with any implant material the presence of bacterial contamination may enhance bacterial infectivity. Accepted surgical practice must be followed with respect to drainage and closure of infected or contaminated wounds. Users should be familiar with surgical procedures and techniques involving synthetic absorbable materials before employing  OptiFix™ Open Absorbable Fixation System fasteners for wound closure, as the risk of wound dehiscence may vary with the site of application and the material used. The device may not fixate through prosthetics derived from biologic material such as xenografts and allografts. Prosthetic should be evaluated for compatibility prior to use. 

Precautions

 Please read all instructions before using the  OptiFix™ Open Absorbable Fixation System. 2. Only persons having adequate medical training and familiarity with surgical techniques should perform surgical procedures. Consult the medical literature relative to technique, complications and hazards prior to any surgical procedure. 3. Counterpressure should be applied on the target area. Avoid placing hand/finger directly over the area where fastener is being deployed to prevent injury. 4. Use caution when applying the  OptiFix™ Open fastener over or in proximity to underlying bone, vessels, nerves, or viscera. The intended fixation site should be assessed to ensure that while the tissue is compressed the total distance from the surface of the tissue to any underlying structures is greater than the length of the  OptiFix™ Open fastener. 5. Insertion of fasteners is possible into some collagenous structures such as ligaments and tendons, but is NOT possible directly into bone or cartilage. This may damage the device and result in compromised fixation strength. 6. Care should be taken not to use excessive counterpressure as this may damage the distal tip of the device as well as the mesh and/or tissue. 7. If the device locks and cannot be separated from a fastener that has been deployed into mesh and/or tissue, place a grasper adjacent to the deployed fastener and pull to free the device. If needed, you may use laparoscopic scissors to cut below the fastener head. The remaining portion of the fastener stem left in the mesh can be removed with graspers. The device should then be discarded and a new device should be used. 8. If the fastener does not deploy properly, remove the device from the patient and test the device in gauze to ensure proper fastener deployment. Once proper fastener deployment is confirmed, the device may be reinserted into the patient.  

Adverse Reactions

Adverse reactions and potential complications associated with fixation devices such as the OptiFix™ Open Absorbable Fixation System may include, but are not limited to the following: hemorrhage; pain, edema and erythema at wound site; allergic reaction to Poly(D, L)-lactide; infection/septicemia; hernia recurrence/wound dehiscence.

Please consult product labels and inserts for any indications, contraindications, hazards, warnings, precautions and instructions for use.

true
Specification

GTIN - Each

00801741128950

1

GTIN - Box

10801741128957

5

GTIN - Case

10801741128957

5


Quantity

5 c/s


Dimensions

OptiFix™ Open Absorbable Fixation System - 20 Absorbable Fasteners

GTIN

GTIN - Each 00801741128950 1
GTIN - Box 10801741128957 5
GTIN - Case 10801741128957 5

Packaging

Quantity 5 c/s

Product Basic Specification

Dimensions OptiFix™ Open Absorbable Fixation System - 20 Absorbable Fasteners
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions
false
References
false
Related Products
RELATED PRODUCTS NOT AVAILABLE
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false
false