Choose “the least invasive VAD with the smallest outer diameter and fewest number of lumens needed to complete the duration and prescribed therapy...”
A robust family of catheters
All PowerPICC™ Catheters combine the efficiency of peripherally inserted central catheter (PICC) access and power injection into one catheter.
The PowerPICC™ family of products can be paired with Sherlock 3CG+™ Tip Confirmation for bedside placement and real-time tip confirmation.
Experience the efficiency of power injection
PowerPICC™ Catheters combine the efficiency of peripherally inserted central catheter (PICC) access and power injection into one catheter.
Multiple configurations
Indicated for short or long-term peripheral access to the central venous system for intravenous therapy
Power injection
PowerPICC™ Catheters allow injection of contrast media for CECT (contrast-enhanced computed tomography) scans with a maximum rate of 5 mL/sec
Kink resistant
PowerPICC™ Catheters feature a reverse taper design and provide kink resistance
Variety of tray configurations
Available in multiple configurations for placement in the interventional radiology (IR) suite or at the patient bedside utilizing maximal barrier components
Clearly labeled
PowerPICC™ Catheters are clearly labeled to differentiate them from all PICCs not indicated for power injection
Blood collection | PowerPICC™ is indicated for blood sampling on 4 French or larger catheters |
StatLock™ Stabilization Device compatible | The catheter features a winged hub compatible with the Statlock™ Stabilization Device, eliminating the need for sutures |
CVP monitoring | All PowerPICC™ Catheters are indicated for CVP monitoring. It is recommended that a catheter lumen of 20 G or larger is used |
Real-time tip location and confirmation technology
Ultrasound and imaging technologies help you visualize vessels, needle trajectory and final catheter tip location
Offers clamp-free extension legs, saline-only care and maintenance and does not require the use of heparin
Smaller-diameter* PICCs that maintain high performance for infusion therapy
Smaller-diameter* PICCs that maintain high performance for infusion therapy without the need for heparin flush solution
Features a unique push-button shielding mechanism, which the clinician activates to quickly retract into the safety barrel
Featuring a notched needle technology that enables rapid visualization of blood return among the catheter shaft
*Size comparison in relation to the PowerPICC™ Catheters of the same lumen configuration.
The flow rate you need in the size you want
When infusion therapy delivery is critical to patient care, the high flow rates of the 5 French triple lumen PowerPICC™ HF Catheter deliver prescribed therapy in the triple lumen PICC without disrupting gravity or pump infusions.
Designed to deliver high pump and gravity flow rates with low pressure
Comparable to the 5 French dual lumen PowerPICC™ Catheter
Small French size*
Facilitates placement in smaller veins, mitigating the risk of thrombosis1
Triple lumen
Configuration enables multiple infusion therapies and blood sampling
Open-ended catheter design
Allows for central venous pressure (CVP) monitoring
*Compared to other triple lumen PICCs, 6 French or greater
At only 5 French in diameter, the triple lumen PowerPICC™ HF catheter supports compliance efforts with key Infusion Nursing Society (INS) recommendations.1
Choose “the least invasive VAD with the smallest outer diameter and fewest number of lumens needed to complete the duration and prescribed therapy...”
“The appropriate vascular access device (VAD), peripheral or central, is selected based on the prescribed therapy or treatment regimen, anticipated duration of therapy, vascular pathway, patient’s age, comorbidities, history of infusion therapy and vascular access, patient preference for VAD type and location, overall vascular health (history of difficult intravenous access, vessel, and skin health at insertion site), and ability and resources available to care for the VAD.”
Real-time tip location and confirmation technology
Ultrasound and imaging technologies help you visualize vessels, needle trajectory and final catheter tip location
Offers clamp-free extension legs, saline-only care and maintenance and does not require the use of heparin
Smaller-diameter* PICCs that maintain high performance for infusion therapy
Smaller-diameter* PICCs that maintain high performance for infusion therapy without the need for heparin flush solution
Features a unique push-button shielding mechanism, which the clinician activates to quickly retract into the safety barrel
Featuring a notched needle technology that enables rapid visualization of blood return among the catheter shaft
*Size comparison in relation to the PowerPICC™ Catheters of the same lumen configuration.
Designed to fit
PowerPICC™ FT Catheters are designed to better fit with the patient’s veins.
Designed from the insertion site to the central venous system
The PowerPICC™ FT Catheter is designed with a reverse taper and provides kink resistance. It features a smaller diameter, flexible midsection designed for dwelling in the small peripheral veins of the upper arm, and a larger distal tip designed to provide stability in the smaller peripheral veins.
Reverse taper
Designed with a reverse tape and provides kink resistance
Optimized lumens
Designed to deliver high pump and gravity flow rates with low pressure comparable to the 5 French dual lumen PowerPICC™ Catheter
Real-time tip location and confirmation technology
Ultrasound and imaging technologies help you visualize vessels, needle trajectory and final catheter tip location
Offers clamp-free extension legs, saline-only care and maintenance and does not require the use of heparin
Smaller-diameter* PICCs that maintain high performance for infusion therapy
Smaller-diameter* PICCs that maintain high performance for infusion therapy without the need for heparin flush solution
Features a unique push-button shielding mechanism, which the clinician activates to quickly retract into the safety barrel
Featuring a notched needle technology that enables rapid visualization of blood return among the catheter shaft
*Size comparison in relation to the PowerPICC™ Catheters of the same lumen configuration.
A powerful solution to serve small patients
The PowerPICC™ Small Vein Catheters provide you with a comprehensive offering of a power injectable peripherally inserted central catheters (PICC), focused on the needs of patients with small veins.
Designed from the insertion site to the central venous system
The PowerPICC™ SV Catheter is indicated for short or long-term peripheral access to the central venous system for intravenous therapy, blood sampling and power injection of contrast media, and allows for central venous pressure monitoring.
Power injection rates
PowerPICC™ SV Catheters allow injection of contrast media for CECT scans with a maximum rate of 1 mL/sec (3 French single lumen) and 2.5 mL/sec (4 French dual lumen)
Small catheter size
Helps clinicians comply with 2024 Infusion Nursing Society (INS) guidelines to ensure a catheter-to-vessel ratio of less than 45% and to use the least invasive VAD with the smallest outer diameter and fewest number of lumens
Reverse taper design
Features a reverse taper design and provides kink resistance
StatLock™ Stabilization Device compatible
Winged hub is compatible with the Statlock™ Stabilization Device, eliminating the need for sutures
*Compared to other triple lumen PICCs, 6 French or greater
Real-time tip location and confirmation technology
Ultrasound and imaging technologies help you visualize vessels, needle trajectory and final catheter tip location
Offers clamp-free extension legs, saline-only care and maintenance and does not require the use of heparin
Smaller-diameter* PICCs that maintain high performance for infusion therapy
Smaller-diameter* PICCs that maintain high performance for infusion therapy without the need for heparin flush solution
Features a unique push-button shielding mechanism, which the clinician activates to quickly retract into the safety barrel
Featuring a notched needle technology that enables rapid visualization of blood return among the catheter shaft
*Size comparison in relation to the PowerPICC™ Catheters of the same lumen configuration.
Experience the efficiency of power injection
PowerPICC™ Catheters combine the efficiency of peripherally inserted central catheter (PICC) access and power injection into one catheter.
The flow rate you need in the size you want
When infusion therapy delivery is critical to patient care, the high flow rates of the 5 French triple lumen PowerPICC™ HF Catheter deliver prescribed therapy in the triple lumen PICC without disrupting gravity or pump infusions.
Designed to fit
PowerPICC™ FT Catheters are designed to better fit with the patient’s veins.
A powerful solution to serve small patients
The PowerPICC™ Small Vein Catheters provide you with a comprehensive offering of a power injectable peripherally inserted central catheters (PICC), focused on the needs of patients with small veins.