{"AlternateComparison":false,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
Venovo™ Venous stents Venovo™ Venous Stent System

Venovo™ Venous Stent System

Icon to close the modal
Support
Becton Dickinson Australia & New Zealand
Phone Icon
AU: 1800 656 100
NZ: 0800 572 468
Modal Close Icon
Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
For more information, please visit our Contact Us page
Overview

Venous disease is complex, your stent choice doesn't have to be

  • Engineered to provide the optimal balance between radial force, flexibility, and compression resistance
  • Tri-axial delivery system designed to provide accurate deployment to help facilitate optimal stent placement and lesion coverage
  • 3mm flared stent ends designed to reduce the risk of stent migration and maximise wall apposition
  • Wides range of sizes ranging from 10mm to 20mm in diameter and 40mm to 160mm in length

 

 

true
Features and Benefits
Promotional Story
Dr. Michael Dake Discusses the 24-Month Results of the Venovo™ Venous Stent VERNACULAR Trial
quote-icon
At a Glance: 24-Month VERNACULAR Results

true
Specification

GTIN - Each

00801741101939

1


Stent Diameter

10 mm

Stent Length

40 mm

Catheter Length

80 cm

Guidewire Type

0.035"

Recommended Sheath

8F

GTIN

GTIN - Each 00801741101939 1

Product Basic Specification

Stent Diameter 10 mm
Stent Length 40 mm
Catheter Length 80 cm
Guidewire Type 0.035"
Recommended Sheath 8F
Electronic Instructions for Use (eIFUs)
Resources
Frequently Asked Questions
false
Related Products
RELATED PRODUCTS NOT AVAILABLE
References

As of September 2022

2Radial resistive force was tested at 13 mm crimp diameter (1 mm oversizing) using a radial expansion force gauge. Results shown as averages measured in N/mm as follows (n=6): Venovo™ Venous Stent System (0.126), Medtronic Abre™ Venous Stent (0.1035), Cook Zilver® Vena™ (0.063) and Boston Scientific VICI VENOUS STENT® (0.054). Data on file. Bench tests may not be indicative of clinical performance. Different test methods may yield different results. 

3Foreshortening is calculated as the difference, represented as percentage, between the compressed stent length and expanded stent length at minimum/maximum oversize (1-3 mm). Across all sizes, foreshortening ranged from -4% to 10%, with a mean of 2.9% (values based on mathematical calculations). Data on file, BD Peripheral Intervention, Tempe, AZ.

Please consult Instructions for Use for product indications for use, contraindications, warnings, precautions, potential complications, adverse events and detailed safety information.

BD - 23533v3

true
true